How to protect the sealing performance of automobile lines

When repairing automobile lines, all body holes and sealing rings for the threading strings at the holes should be put in place, because these sealing rings not only function as seals but also serve as protective harnesses. If the seal ring is damaged or the wire harness can rotate or move in the seal ring, replace the seal ring, and assemble it firmly with the body holes and holes to stabilize the wire harness.

After the window glass is damaged, it is necessary to change the glass with the same curvature as the original window glass, and at the same time check whether the glass guide groove and the sealing strip are damaged. Since the windows do not always return to their original shape after repair, it is necessary to ensure that the window glass can be sealed tightly after the window is closed, in addition to ensuring that the window glass can be easily pulled or lifted.

When repairing a door with a sealing flange, care should be taken to repair the damaged sealing flange and accurately restore the shape of the original flange. After the door is repaired, check the leak tightness. The inspection method is: Place a piece of hard paper on the sealing position, close the door, pull the piece of paper again, and judge whether the seal is good or not according to the size of the pulling force. If too much force is required to pull the piece of paper, it means that the seal is too tight, which affects the normal closing of the door, and also causes the seal to change its sealing performance quickly due to excessive deformation; if the force needed to pull the piece of paper is exceeded If it is too small, it indicates that the seal is bad, and the door wind is often not protected from rain. When replacing the door, it is necessary to pay attention to the folding edge glue on the inner and outer flanges of the new door, and to plug some of the small holes left in the stamping process with the base tape.

When changing the roof, firstly apply a layer of conductive sealant at the pressure joint of the roof, and then apply the folded edge glue in the flow tank and joints after welding. This will not only help to seal the body, It can also prevent the car body from causing early corrosion due to the accumulation of water at the flange weld. When assembling the door, it is necessary to affix a whole piece of sealing and isolating film to the inner panel of the door below the window. If there is no formed sealing isolation film, ordinary plastic paper can be used instead, and then the sealing and separating film can be affixed and compacted, and finally carried out. Interior panel production assembly.

When replacing the entire vehicle body, besides the above items, the seals should be applied to the overlapping parts of the welds and the solder joints. The thickness of the adhesive layer should be approximately 1 mm, and the adhesive layer should not be viscous. Defects such as air bubbles, etc.; special hemming adhesives should be applied on the folded edge, and 3mm-4mm of elastic coating and anti-corrosion coating should be applied on the under floor surface and the front surface of the front wheel cover. The inner surface of the board is to be affixed with sound-insulating, heat-insulating, vibration-damping film, then covered with heat-insulating mats, and finally carpeted or decorated with a decorative floor. These measures can not only greatly enhance the vehicle's tightness and reduce the rust speed of the body, but also can greatly improve ride comfort.

Air Conditioner

Air conditioner

Wide application in hotel, commercial building

Air Conditioner. It refers to the process of adjusting and controlling the parameters such as temperature, humidity, cleanliness and speed of the ambient air in the building/structure by manual means.

Generally include cold source / heat source equipment, hot and cold medium distribution system, terminals other auxiliary equipment. It mainly includes pumps, fans and piping systems. The terminals are responsible for utilizing the cooling air or heating air from the main air cooled chiller or Water Cooled Chiller, specifically processing the air and temperature of target environment to meet the requirement.

The main spare parts: compressor, condenser, evaporator and expansion valve.

It includes:

1. Residential Air Conditioner. Such as wall mounted split unit, Ducted Split Unit , floor standing and cassette unit with small cooling capacity 12000BTU, 18000BTU, 24000BTU, 36000BTU, 48000BTU and 60000BTU. This type air conditioner usually used for residential use.

2. Commercial Air Conditioner. Such as Air to air Rooftop Packaged Unit, Air cooled chiller, Water cooled chiller, Industrial chiller and terminals like Air handling unit and Fan Coil unit. Mainly used for commercial building and some project.

DX Type Rooftop Air Conditioner

Air Conditioner,Air Conditioning,Central Air Conditioner,Industrial Air Conditioner